ANDREW CNT 400 COMMSCOPE RF 50ohm LOW LOSS CNT 400 (LMR400) ANDREW Commscope
Low loss RF cable also special for Helium Network, CNT-400 from Andrew, a supplier of many mobile phone companies (base stations) known in the professional telecommunications sector.
The best value for money solution for signal transfer to the antenna without losses, mainly for high frequencies VHF, UHF, (868mhz)
Ideal for permanent installation and durability for many years.
Very hard external PVC plastic for abrasion and cut resistance, single-stranded copper conductor for less weight, silver-plated copper mesh with 99% coverage and aluminum foil for better shielding.
All cables are custom made to your specifications and measured with an instrument to ensure their long-term operation.
CHOOSE ABOVE <Files> TO SEE IN PDF THE MANUFACTURER'S FEATURES
CNT-400, CNT® 50 Ohm Braided Coaxial Cable, variable, black PE jacket
ΚΑΤΑΣΚΕΥΑΣΤΗΣ Commscope
Specifications
Construction Materials | |
---|---|
Jacket Color | Black |
Jacket Material | Non-halogenated PE |
Braid Material | copper tined |
Shield Tape Material | Aluminum |
Dielectric Material | Foam PE |
Inner Conductor Material | Copper-clad aluminum wire |
Dimensions | |
Cable Weight | 0.10 kg/m |
Diameter Over Dielectric | 7.240 mm | 0.285 in |
Diameter Over Jacket | 10.290 mm | 0.405 in |
Diameter Over Tape | 7.391 mm | 0.291 in |
Inner Conductor OD | 2.7400 mm | 0.1079 in |
Nominal Size | 0.400 in |
Outer Conductor OD | 8.080 mm | 0.318 in |
Electrical Specifications | |
Cable Impedance | 50 ohm |
Capacitance | 78.0 pF/m | 24.0 pF/ft |
dc Resistance, Inner Conductor | 4.690 ohms/km | 1.430 ohms/kft |
dc Resistance, Outer Conductor | 5.610 ohms/km | 1.710 ohms/kft |
dc Test Voltage | 2500 V |
Jacket Spark Test Voltage (rms) | 8000 V |
Maximum Frequency | 16.20 GHz |
Operating Frequency Band | 30 – 6000 MHz |
Peak Power | 16.0 kW |
Shielding Effectiveness | >90 dB |
Velocity | 85% |
Environmental Specifications | |
Installation Temperature | -40 °C to +85 °C (-40 °F to +185 °F) |
Operating Temperature | -40 °C to +85 °C (-40 °F to +185 °F) |
Storage Temperature | -70 °C to +85 °C (-94 °F to +185 °F) |
General Specifications | |
Cable Type | CNT-400 |
Braid Coverage | 99% braid |
Brand | CNT® |
Mechanical Specifications | |
Bending Moment | 0.7 N-m | 0.5 ft lb |
Flat Plate Crush Strength | 0.7 kg/mm | 40.0 lb/in |
Minimum Bend Radius, Single Bend | 25.40 mm | 1.00 in |
Tensile Strength | 73 kg | 160 lb |
Frequency | Attenuation (dB/100 m) | Attenuation (dB/100 ft) |
30 MHz | 2.49 | 0.76 |
50 MHz | 3.18 | 0.97 |
150 MHz | 4.92 | 1.50 |
220 MHz | 6.23 | 1.90 |
450 MHz | 8.86 | 2.70 |
900 MHz | 12.80 | 3.90 |
1500 MHz | 16.70 | 5.10 |
1800 MHz | 18.40 | 5.60 |
2000 MHz | 19.40 | 5.90 |
2400 MHz | 21.65 | 6.60 |
2500 MHz | 22.00 | 6.70 |
3000 MHz | 24.60 | 7.50 |
4000 MHz | 28.87 | 8.80 |
4500 MHz | 30.84 | 9.40 |
5000 MHz | 32.81 | 10.00 |
5200 MHz | 33.46 | 10.20 |
5500 MHz | 34.78 | 10.60 |
5800 MHz | 35.76 | 10.90 |
6000 MHz | 36.42 | 11.10 |